Note: Make sure that the handle is always turned in the same direction when moving in the "x"
axis so that you do not back over a previously burnt spot.
11.
Turn the "z" axis up ( 1 ) turn of the handle.
12.
Open the shutter and turn the handle in the negative( down ) direction until you see a blue flame
and stop / close the shutter key.
13.
Repeat steps 10 - 12 until a consistent value is obtained within ( ± 0.004" ).
14.
Calculate the average value obtained in step 13 and move the "z" axis to that value using the
handle.
15.
Zero all axis in the "MANUAL ORIGIN" mode.
>
press the "M" (menu) key twice.
>
press the "ORIGIN KEY".
>
press "0" then "INPUT" ( X axis )
>
press "0" then "INPUT" ( Y axis )
>
PRESS "0" then "INPUT"
16.
Lower the "z" axis to
Note: If a " - Z SOFT OVERTRAVEL " alarm occurs perform the following:
Note: If the "z" axis cannot be adjusted to ( - 0.3000 ) repeat steps 5 - 16 over ( the blue flame
was passed ).
17.
Make a small movement in the "X" axis ( approx. 1/4 turn ).
18.
In "HANDLE", "Z", "X10" open the shutter key and turn the handle in the positive ( up )
direction until you see a blue flame and stop / close the shutter key.
19.
Repeat steps 16 - 18 until a consistent value is obtained within ( ± 0.004" ).
20.
Calculate the average value obtained in step 19, divide by ( 2 ) and move the "z" axis to that
position using the handle.
Note: the position will be negative.
( - 0.3000)
-
RAISE THE "Z" axis slightly
-
Press "RESET"
-
Press "MANUAL"
-
Press "LASER"
-
Press"INPUT" ( 5 ) times
( Z AXIS )
20
Need help?