NOZZLE CENTERING:
34.
Raise the "z" axis and remove the stainless plate.
35.
In "MANUAL LASER" input the following:
"PEAK POWER"
"FREQUENCY"
"DUTY"
"PRESSURE"
Press "NORMAL PULSE"
Press "OXYGEN"
Press "INPUT"
36.
Place a piece of tape over the end of the nozzle and lower the "Z" axis so that the nozzle is at the
approximately cutting height using the "HANDLE MODE".
Note: the shutter will not open unless "HANDLE" OR "JOG" is highlighted.
37.
Quickly open and close the shutter key.
38.
Raise the "z" axis and adjust the nozzle for centering using the knurled knobs at the base of the
torch.
Note: the nozzle is being moved, not the pierced hole.
39.
Repeat steps 37 - 39 until the beam is centered.
40.
Press "reset"
300
INPUT
100
INPUT
7
INPUT
0
INPUT
22
Need help?