Technical Data - Assa Abloy Crawford MCS-R Installation Manual

Replacing ecs 430p or older control units
Table of Contents

Advertisement

MCS-R Control unit
replacing ECS 430P or older control units for
CDM5 & 6
2.2

Technical data

Dimensions:
Main supply voltage L1, L2, L3, N, PE:
Fuse protection:
Voltage:
Access input:
Safety circuit / Emergency stop:
Input safety rail:
Relay output:
Temperature range:
Atmospheric humidity:
Protection
Weight
MCS-R control unit
350 x 200 x 120 mm
400V 50Hz
10A K- characteristic
24V DC, max. 320mA
24V DC, All inputs must be absolutely potential free. Minimum duration of input
signal control command >100ms
Connect all inputs absolutely potential free; at interruption in the security circuit,
it is not longer possible of electrical operation of the motor, even in hold-to-run
mode.
For electrical safety strips with 8.2kΩ, load resistor and for dynamic optical systems
If used as power switching contacts, it cannot serve more small electric currents,
max 2A
-15°C - +50°C
Max. 80% non-condensing.
IP 54 (in housing)
Ca. 2.2 kg
Installation Manual
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents