Technical Data - Assa Abloy Norton 6300 Pull Side Series Installation And Instruction Manual

Full feature low energy operator
Table of Contents

Advertisement

Door Prep
Hollow Metal Door Frame Reinforcing
Frame
Material
Recommended
12 Ga.
.1046
(2.66)
14 Ga.
.0747
(1.90)
16 Ga.
.0598
(1.52)
18 Ga.
.0478
(1.21)
Fasteners for Frame:
• 1/4-20 Machine screws for hollow
metal and aluminum.
• No. 14 x 2-3/4 " (70mm) long sheet
metal screws for wood.

Technical Data

Input power:
Power supply:
Door width:
Door weight:
Push min angle:
Push max angle:
Pull max angle:
Hold open time:
Standards
ETL Certified; conforms to ANSI/UL standard 325 for
automatic closing doors and UL10C Positive Pressure Fire
Test for Door Assemblies .
ANSI A156.19:
These products are designed to conform to this specification
"for power assist and low energy power operated doors."
These products are designed to exceed all the requirements
for the "Low Energy Power Operated Door."
Copyright © 2017 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Reinforcing
Min. Required
12 Ga.
18 Ga.
.1046
.0478
(2.66)
(1.21)
10 Ga.
12 Ga.
.1343
.1046
(3.41)
(2.66)
10 Ga.
12 Ga.
.1343
.1046
(3.41)
(2.66)
8 Ga.
10 Ga.
.1644
.1343
(4.18)
(3.41)
120VAC, 60Hz
24 V DC, max. 6.5 Amp. ; 1.3A Available Acc.
36 - 48" (91-122 cm)
90-200 lb. (41-91 kg)
110° with reveal of 6-3/4" max
130
° with reveal of 1/8" min
180
°
5-30 seconds (A.D.A. 5 seconds min.)
Indefinite for Hold Open Input or cap switch
Templating is based on 1/8" gap between door and frame.
Notes:
• All dimensions are given in inches.
• Thickness recommended for reinforcements in hollow metal doors
and frames is charted at the left of this page.
• Do not scale drawing.
• This template information based upon use of 5" maximum width butt
hinges.
• Maximum frame reveal is 1/8" for 6310 units and 1/8" up to 6-3/4"
maximum for 6330 units.
• Before beginning the installation, verify that the door frame is properly
reinforced and is well anchored in the wall.
• Concealed electrical conduit and concealed switch or sensor wires
should be pulled to the frame before proceeding.
Notes: Permanent wiring is to be employed as
Maximum wire size is:
Americans with Disabilities Act (A.D.A.)
These door operators can be installed and adjusted to
conform with A.D.A. regulations.
ANSI A117.1:
These door controls permit door assemblies to
conform to the requirements of this specification "for
buildings and facilities - providing accessibility and
usability for physically handicap people."
Page 3
Frame
Door
1/8"
(3)
required by local codes.
Activation devices: push plates, access
control, mats, touchless wall switches, etc.
12AWG at terminals LINE and NEUTRAL
(120VAC; 60Hz) on Power Input Terminal.
14AWG at all other terminals.
80-9363-0001-020 Rev 8 11/17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Norton 6310 pull sideNorton 6350 pull side

Table of Contents