LED
Type
Drawer module fault Amber
Logical fault
Drawer cable fault
¹ If all drives are functioning properly, contact Technical Support for assistance.
² Contact Technical Support for assistance.
Drive carrier fault LED
The drive module in its carrier (DDIC) uses a single amber fault LED to identify various states. The asterisk (*) indicates a fault
condition.
62 Chapter 8 Hardware installation and configuration issues
Color
Amber
Amber
Figure 40 5U84 drawer fault LEDs on drawer LED panel
Color
State
On*
Fast flash (1s on, 1s off)
Amber
Slow flash* (3s on, 1s off)
Off
Figure 41 Drive fault LED on carrier bezel
State
Status
Component within drawer fault condition¹
On*
Drive fault¹
Flashing*
Unit ID (UID) or locate is active for drawer sideplane or drive
Off
Drawer modules functioning properly
On*
Drive hardware fault condition
Flashing*
One or more arrays impacted by drive hardware fault conditions
Off
Drive hardware functioning properly
On*
Cable from rear panel to drawer fault condition²
Off
Cables functioning properly
Status
Drive has hardware fault, replace as soon as possible
Drive link down
Unit identification (UID) or locate is active for drive
Drive in critical condition
Failed array
No AC power present
Drive initialization in process
Drive quarantined