Figure 64 Input/Output Module Removal, Left; Figure 65 Replacement Input/Output Module - Seagate Exos E 2U12 Series Hardware Installation And Maintenance Manual

Hide thumbs Also See for Exos E 2U12 Series:
Table of Contents

Advertisement

c. Pull the handle outward to lever the IOM away from the midplane.
d. Use one hand to support the weight of the IOM and the other to gently withdraw the IOM from its slot.
e. Place it in a static-protected location.
2. Complete the following actions to replace it with a tested good IOM:
a. Examine the tested good IOM to make sure it is undamaged with pins that are straight, not bent.
b. Facing the rear of the 5U enclosure, orient the IOM with the open latch identically to the one you removed.
c. Use one hand to support the weight of the IOM and the other to guide it into the empty IOM slot.
d. Exerting even pressure to the center, gently press it against the midplane until the latch closes and locks in place.
3. After verifying the connectors are all undamaged, reconnect all cables as they were connected before.

Figure 64 Input/output module removal, left

Figure 65 Replacement input/output module

Chapter 10   In-service field maintenance for 5U  enclosures
С
С
С
89