Figure 43 Fan Cooling Module Fault Leds; Figure 44 Power Supply Unit Fault Leds - Seagate Exos E 2U12 Series Hardware Installation And Maintenance Manual

Hide thumbs Also See for Exos E 2U12 Series:
Table of Contents

Advertisement

LED
Power supply unit fault LEDs
Each power supply unit (PSU) has three status LEDs. The asterisk (*) indicates a fault condition.
LED
Type
PSU fault AC fault PSU OK
Color
Amber
Flashing
State
On*
Off
Off
64            Chapter 8   Hardware installation and configuration issues
Type
Color
State
On
FCM OK
Green
Off*
On*
FCM fault Amber
Off

Figure 43 Fan cooling module fault LEDs

Status
N/A
Amber
Green
Off
AC power not present
On*
Off
PSU present, but not supplying power
Off
Firmware download to PSU in progress
Off
On
AC power present, power switch is on, providing power
Off
Flashing AC power present, PSU on standby, other PSU providing power
On*
Communication with input/output module (IOM) lost
N/A
Off
PSU hardware fault
On*
Off
PSU alert state or hardware fault: over temperature, over voltage, or over current
On*
Off
AC power failed, PSU not providing power, other PSU providing power
On*
AC power failed, PSU running on battery

Figure 44 Power supply unit fault LEDs

Status
FCM hardware functioning properly
FCM hardware fault: over temperature, over voltage, over current
Fan speed is out of tolerance
Communication with input/output module (IOM) lost
FCM hardware functioning properly

Advertisement