Alliedware Messages - Allied Telesis AT-8900 Hardware Reference Manual

Hide thumbs Also See for AT-8900:
Table of Contents

Advertisement

Hardware Reference
AlliedWare
messages
Software Release 3.0.2
C613-03092-00 REV C
Message
ERROR: Fallback area is
corrupt - launching the
bootloader CLI
ERROR: No main board
personality - launching the
bootloader CLI
No valid installed package -
booting fallback software
ERROR: No valid software
available - launching the
bootloader CLI
ERROR: Package
filename.pkg is not valid
ERROR: ELF header has
problem
ERROR: System image has
no section headers
ERROR: No memory
available for storing ELF
element
The following table explains messages that the base and fallback software
display at startup for the AT-9900s switch.
Message
Alliedware <version>, built
<date>
WARNING: Fallback
software will not allow
normal network operation
Initialising file system
access...done
or
Initialising file system
access...failed
Validating package
licence...done
or
Validating package
licence...failed
Description (cont)
The switch is shifting to bootloader software because the
fallback area in flash is unformatted or corrupt. It displays a
bootloader prompt. Contact your authorised distributor or
reseller before proceeding.
Unique information about the main PCB has not been
programmed and the switch cannot start without it. Contact
your authorised distributor or reseller.
The switch cannot find valid installed software, or files with
install information are corrupt and the fallback area does not
contain a valid file. The switch starts from fallback software.
See the Managing Configuration Files and Software Versions
chapter in the Software Reference for information about
installation procedures, including the set install command.
The switch is shifting to bootloader software because it
cannot find a valid package. It displays a bootloader prompt.
Contact your authorised distributor or reseller before
proceeding.
The switch could not extract the system image file because of
a problem with the given package. Install a different package
from fallback. Contact your authorised distributor or reseller
if the problem continues.
The system image file is corrupt or invalid due to the reason
given.The switch tries to start from fallback software. If this
fails, contact your authorised distributor or reseller.
The system image file is corrupt or invalid because it has no
section header information. Contact your authorised
distributor or reseller.
A serious problem exists with memory allocation software or
memory on the switch. Contact your authorised distributor
or reseller.
Description
Banner that identifies the product software the switch is
executing—base or fallback.
When starting from fallback software, a reminder that
fallback is a subset of the product software and does not
have its full functionality.
Product software has initialised access to the file system.
Failure means a problem with the file system or flash.
Processing will continue but data will be lost. Contact your
authorised distributor or reseller.
Whether a valid licence has been found for the base package.
Verify licence, version, and switch model and contact your
authorised distributor or reseller if necessary. Not displayed
for fallback.
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

At-9900At-9900sAt-8948At-9924tAt-9924spAt-9924ts

Table of Contents