Allied Telesis AT-FAN01 Installation Manual
Allied Telesis AT-FAN01 Installation Manual

Allied Telesis AT-FAN01 Installation Manual

Removable power supply and fan
Hide thumbs Also See for AT-FAN01:

Advertisement

Quick Links

Removable Power Supply and Fan
Installation Guide
AT-PWR01
AT-PWR02
AT-PWR05
AT-FAN01
AT-FAN03

Advertisement

Table of Contents
loading

Summary of Contents for Allied Telesis AT-FAN01

  • Page 1 Removable Power Supply and Fan Installation Guide AT-PWR01 AT-PWR02 AT-PWR05 AT-FAN01 AT-FAN03...
  • Page 2: Installation Guide

    Removable Power Supply and Fan Installation Guide AT-PWR01 AT-PWR02 AT-PWR05 AT-FAN01 AT-FAN03 Download the complete document set from www.alliedtelesis.com/support/software...
  • Page 3 Removable Power Supply and Fan Installation Guide Document Number C613-04057-00 REV L © 2008 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis, Inc. reserves the right to change specifications and other information in this document without prior written notice.
  • Page 4: Table Of Contents

    Installation Guide Contents About this Guide ... 4 Compatible Switches ... 4 Package Contents ... 5 Installing a Power Supply Unit or Fan ... 6 Connecting an AC power supply ... 9 Connecting a DC power supply ... 11 Checking LEDs ... 13 Removing a Power Supply Unit or Fan ...
  • Page 5: About This Guide

    AT-PWR01 PSU, either AC or DC power supply unit ■ AT-PWR02 PSU, AC only ■ AT-PWR05 PSU, AC only ■ AT-FAN01, fan-only module ■ AT-FAN03, chassis fan module Compatible Switches The following table shows which models of PSUs and fans are appropriate for individual switches.
  • Page 6: Package Contents

    PSUs. The following items are included with each factory-installed PSU. Contact your authorised Allied Telesis distributor or reseller if any are damaged or missing. ■ one AC power cord (AC models) ■...
  • Page 7: Installing A Power Supply Unit Or Fan

    Caution Follow correct anti-static procedures. Failure to do so could damage the PSU, fan, or switch. If you are unsure about correct procedures, contact your authorised Allied Telesis distributor or reseller. Caution When adding or replacing power supplies, keep your hands and fingers out of the power supply bays.
  • Page 8 Installing a PWR01, PWR02, or FAN01 If you are replacing a PSU, disconnect the power cord from the currently installed PSU before removing it. For AC PSUs, turn off the main power source to the PSU and disconnect the power cord. For DC PSUs, push the Run/Standby control and release it to the Off position.
  • Page 9 Removable Power Supply and Fan Installing a PWR05 or FAN03 If you are replacing a PSU, turn off the main power source to the PSU and disconnect the power cord before removing it. The DC earthing connection is not necessary for the SwitchBlade x908 when using AC PSUs because the chassis is grounded through the power cords.
  • Page 10: Connecting An Ac Power Supply

    Connecting an AC power supply Follow these instructions to connect an AT-PWR01, AT-PWR02, or AT-PWR05 AC PSU to an AC power supply: Warning The AT-PWR01 AC PSU has a fuse rating of 250V, 5A for FH101 and FH102. Warning The AT-PWR01 AC PSU has double pole/neutral fusing. Electric shock is possible since there are dual primary fuses, one on the phase circuit and one on the neutral circuit.
  • Page 11 Removable Power Supply and Fan Connect the power cord to the main power source. Check that the Run/Standby switch is set to the Run position (1). Both the AC and DC LEDs should be lit. Run/Standby Note that when the Run/Standby switch is set to the Standby position (0), the AC LED lights and the fan spins, but the DC LED does not light and the PSU does not deliver power to the device.
  • Page 12: Connecting A Dc Power Supply

    Connecting a DC power supply Follow these instructions to connect an AT-PWR01-80 DC PSU to a DC power supply. Only trained and qualified personnel should connect a DC power supply. You need an appropriate DC power source, DC supply cable, ring connectors, a crimp tool and an appropriate screwdriver to tighten the terminal screws.
  • Page 13 Removable Power Supply and Fan Ensure there are no exposed cable strands. Replace the cover. You must replace the transparent plastic terminal cover before continuing. Secure the supply cable to the rack framework or a similar object to ensure that connections are isolated from any force applied to the cable. Ensure the circuit breaker for the supply circuit and the Run/Standby control on the PSU are off.
  • Page 14: Checking Leds

    Checking LEDs LEDs on PSUs, fans, and the front panels of switches indicate the operational status of the devices. After you have installed a PSU or fan and have powered on the switch, check the LEDs to verify operation by using the following tables. PWR01 The following table describes LEDs on the PWR01 and PWR02 power supply units.
  • Page 15 Removable Power Supply and Fan Switch The following table describes how LEDs on the switch report operations and faults with installed PSUs and FOMs. State PSU 1 Green PSU 2 Description The PSU is installed and supplying power to the switch. The voltage output is within specification.
  • Page 16: Removing A Power Supply Unit Or Fan

    Caution Follow correct anti-static procedures. Failure to do so could damage the PSU, fan, or switch. If you are unsure about correct procedures, contact your authorised Allied Telesis distributor or reseller. Caution Keep your hands and fingers out of the power supply bays.
  • Page 17: Troubleshooting

    Removable Power Supply and Fan Troubleshooting If the PSU does not function as expected: ■ Check that all cable connections are correct and secure. ■ On the PWR01 DC model, check that the Run/Standby switch has been pressed and is in the On position. ■...
  • Page 18: Obtaining Documentation And Resources

    You can download it from www.adobe.com. Other resources How-To Notes describe a range of standard Allied Telesis solutions, and include technical tips and guides to configuring specific hardware and software features. You can download the latest How-To Notes from www.alliedtelesis.com/resources/literature/howto.aspx.
  • Page 19 Contacting us With locations covering all of the established markets in North America, Latin America, Europe, Asia, and the Pacific, Allied Telesis provides localized sales and technical support worldwide. To find the representative nearest you, visit us on the Web at www.alliedtelesis.com.
  • Page 20: Standards

    Standards Products in this document meet the following standards: Category Electromagnetic Compliance Immunity U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 21: Ec Declaration Of Conformity

    Removable Power Supply and Fan EC Declaration of Conformity ALLIED TELESIS LABS LIMITED 27 NAZARETH AVENUE CHRISTCHURCH 8024 NEW ZEALAND Declare under our sole legal responsibility that these products: AT-PWR01, AT-PWR01-80, AT-PWR02, and AT-PWR05 Are in conformity with the essential requirements of directives: ■...

Table of Contents