24
Message
Installing product_apps.img
(8925892 bytes)...done
or
Installing product_apps.img
(8925892 bytes)...failed
IGMP packet trapping has
been activated for IGMP
snooping
Executing configuration
script <startup.cfg>
Switch startup complete
ERROR: Phase 1 of Software
Manager startup failed -
rebooting
WARNING: Bad board of
type <number> in
Expansion Bay <number>
WARNING: Unsupported
board of type <number> in
Expansion Bay <number>
Unit was rebooted because
of a system exception
Creating core file
system_release-
number.core...done
or
Creating core file
system_release-
number.core...failed
ERROR: Unable to read
fallback package
information
ERROR: Unable to read
preferred or temporary
install information
AT-8900, AT-9900, AT-9900s Series Switches
Description (cont)
Whether the product application image of the given size is
installed in RAM and able to execute. This file is part of the
installed package.
Failure could mean not enough RAM or the package is
corrupt. Contact your authorised distributor or reseller.
IGMP packet trapping is enabled to allow IGMP snooping to
function. A warning is displayed if this function could not be
activated. Not displayed for fallback.
Configuration commands in the given script file begin
executing if selected by the user. If the script has an error,
appropriate error messages are displayed.
The startup process is complete and the switch is ready. If
devices connected to it are sending traffic, then the switch
begins switching operations.
AlliedWare Error Messages
Software Manager is part of the system software that
controls startup of the product software. It failed to complete
the first phase of its initialisation and cannot boot the
fallback software. Manually restart the switch with fallback
software (for details, see
"Overrides" on page
If this error occurs while rebooting from fallback, contact
your authorised distributor or reseller.
Board personality of the given type in the given bay could not
be read. Possible causes include:
• unprogrammed personality PROM on the board
• faulty hardware on expansion or host board
For information about boards, see the show system boards
command in the Configuring and Monitoring the System
chapter in the Software Reference.
Software does not support the board of the given type in the
given bay.
The switch is restarting after a system exception. Depending
on the exception, you may need to contact your authorised
distributor or reseller.
Displayed after the switch restarts itself, and indicates
whether system core information has been written to the
specified file. Each image file creates its own core file and
coredump. This information is loaded into RAM after a
system exception and before the switch restarts. Contact
your authorised distributor or reseller.
Information about fallback software is not available. Contact
your authorised distributor or reseller.
Information is not available about the type of install
indicated. The switch tries to start from fallback software. If
this fails, contact your authorised distributor or reseller.
20).
Software Release 3.0.2