5.5 Piping

5.5.1 Connecting the piping (stationary installation – 5 metre cable length)
NOTE
Connect the pump and piping at the G 1¼ thread of the discharge nozzle. Use a
pipe with an inner diameter of 32 millimetres.
5.5.2 Connecting the piping (transportable installation – 10 metre cable length)
1. A hose with an inner diameter of 30 millimetres can be connected to the
pump set. To do so, screw a G 1 ¼ adaptor into the threaded socket (see
accessories "drainage hose set A 25 B").
2. Fasten the hose with a hose clip.
5.6 Installing the pump set
Figure 6. Installation dimensions and switching levels.
Cut-in level
Cut-out level
1. If required, suspend the pump set using a rope attached to the handle.
2. Place the pump set on a solid surface.
Observe the recommended installation dimensions.
3. Position the pump set so that the float can move freely.
5.7 Connection to power supply
Plug the pump into the mains socket.
The pump switches on and off automatically.
Delta V3, V4, V6 Submersible Pump
The highest point of the discharge line must be above the flood level (usually street
level) to prevent any backflow from the sewage system.
E
5 Installation at site
Table 5. Recommended installation dimensions.
Pump set
Delta V3
Delta V4, V6
Installation and operating manual
E (mm)
h (mm)
400x400
400
400x400
500
19 of 32