Table 26: Potential Field Connections and Locations
(Sizes 060-100)
Label
Description
24+
Supply Voltage
N24
Supply Voltage Common
236
Sensor Common
+24V
Sensor Power MCB
+24V-A
Sensor Power EXP-A
Condensate Overflow
202
Switch
208
Outdoor Air Humidity
208E
Space Humidity Sensor
208G
Return Air Humidity Sensor 0-10VDC Input
213
Space CO2
220
Freeze Stat
SCR Electric Heat/Electric
222
Heat Stage 1
222C
Chilled Water Valve Output 24VAC Output
223
Electric Heat Stage 2
224
Electric Heat Stage 3
225
Electric Heat Stage 4
228C
Hot Water Valve Output
232A
Dirty Filter Switch
TB2
247
Leving Coil Temp
249
Compressor 1/Vlv1 On Off
251
Compressor 2
254
Compressor 3
256
Compressor 4
267
Supply Fan Signal
275
Exhaust Fan Signal
277
Outdoor Air Damper
281
Discharge Air Temp
282
Return Air Temp
297
Outdoor Air Temp
299
Emergency Stop
2120
Air Flow Switch
2124
Duct Static Pressure
2130
Damper End Switch
2133
Return Air Damper
2140
VAV Box Output
Modulating Chilled Water
2150
Valve
www.DaikinApplied.com
PreciseLine units operate with 115V and 24V control circuit
power. All field control wiring connections are made at the class
II terminal blocks TB2, TB4, and TB12 which is located in the
Signal
Low Voltage Control Panel, shown in
24VAC Output Supply
Ground
NOTE: The installation of all field wiring, must comply with all
Sensor Common
24VDC Supply MCB
24VDC Supply EXP-A
Discrete Contact Closure
0-10VDC Input
0-10VDC Input
Emergency Stop
0-10VDC Input
The terminals TB12-T10 & TB2-Ground on sizes 006-050 and
24VAC Contact Closure
TB2-299 & TB2-236 on sizes 060-100 can be used for any
0-10VDC Output/24VAC
Output
field supplied component that requires a unit emergency stop.
When these terminals are used, the factory installed jumper
24VAC Output
must be removed.
24VAC Output
24VAC Output
24VAC Output
Discrete Contact Closure
Thermistor Input
24VAC Output
24VAC Output
24VAC Output
24VAC Output
0-10VDC Output
0-10VDC Output
0-10VDC Output
Thermistor Input
Thermistor Input
Thermistor Input
Discrete Contact Closure
24VAC Contact Closure
0-10VDC Input
Discrete Contact Closure
0-10VDC Output
24VAC Output
0-10VDC Output
41
applicable local codes and ordinances. The warranty
may be limited or certain aspects excluded if the field
wiring is not in accordance with these standards.
If a single conduit containing 24V and 115V wiring is
run above the roofline between units, consider the
24V wiring within as an NEC Class I wiring system.
IM 1267-7 • PRECISELINE AIR HANDLER