Introduction

Hazardous Information Messages

CAUTION
Caution indicates a potentially hazardous situations, which can result in
minor injury or equipment damage if not avoided.
WARNING
Warning indicates a potentially hazardous situations, which can result in
property damage, personal injury, or death if not avoided.
DANGER
Danger indicates a hazardous situation, which will result in death or serious
injury if not avoided.
NOTICE
Notice indicates practices not related to physical injury.
Consider Before Operation
WARNING
Improper installation maintenance can cause equipment
damage or personal injury.
Installation and maintenance must be performed by qualified personnel
familiar with applicable codes and regulations, and experienced with this
type of equipment.
CAUTION
PreciseLine units are not designed to be weather resistant; DO NOT install
outdoors.
DANGER
Improper ground may result in severe injury or death.
Check grounding nut tightness before connecting power to the external
junction box.

Storing the Unit

Store unit on a level surface. If air handling units are to be
stored for any period of time, it is important to rotate the motor
shaft (quarterly, as a minimum) to prevent permanent distortion
of drive components.
Store units indoors in a clean, dry environment on a level
surface. Moisture, debris, and minerals can cause permanent
damage to the cabinet and components. Do not allow
coverings to trap moisture on the galvanized surface.
When in a warehouse (i.e. not in transit), horizontal units Size
006-020 can be stored 3 units high. Vertical units Size 006-
020 can be stored 6 units high without an external filter rack,
and 5 units high with one. Do not stack units Size 030 and
larger.
www.DaikinApplied.com
Smoke Control and Management
Systems
Improper smoke or fume air handling can result in severe
personal injury or death.
A registered professional engineer must design and approve the air
conditioner and air handler application to make sure smoke and fume
control meet local fire codes and NFPA requirements for the specific
building application. Due to the wide variation in building design and
ambient operating conditions into which our products can be applied,
we do not represent or warrant that our products will be fit and sufficient
for smoke and fume control and management purposes. The owner and
building designer must consult a registered professional engineer to satisfy
themselves in this regard.
The system design and installation must follow accepted
industry practice, such as described in the
Handbook, the
National Electric
standards. The installation of this equipment must be in
accordance with regulations of authorities having jurisdiction
and all applicable codes. It is the responsibility of the installer
to determine and follow the applicable codes.

Receiving and Handling

1. Carefully check items against the bills of lading to verify
all crates and cartons were received. Carefully inspect
all units for damage when received. Report visible and
concealed damage immediately to the carrier and a file a
claim for damage within 5 days.
2. PreciseLine air handler units are thoroughly inspected
before leaving the factory. Install units carefully to
prevent damage.
3. All fans are dynamically balanced before leaving the
factory. Carefully inspect fans for rough handling that can
cause misalignment or a damaged shaft.
4. Horizontal units Size 006-020 may be stacked 3 units
high for transit.
5. Vertical units Size 006-020 may be stacked for transit
4 units high without external filter rack and 3 units with
external filter rack.
6. Never stack units Sizes 030-100
3
IM 1267-7 • PRECISELINE AIR HANDLER
Introduction
WARNING
ASHRAE
Code, and other applicable