Connecting Discharge Piping - Pentair STA-RITE PNC Owner's Manual

Shallow well jet pumps/tank systems
Table of Contents

Advertisement

Available languages

Available languages

Discharge Pipe and Pressure Tank Connections
To Household
Water System
Pressure
Switch
Figure 4: Pre-charged Tank Connections
To Household
Water System
Pump Priming
Tee and Plug
Pressure
or Gauge
Switch
Figure 5: Standard Tank Connections
PRE-CHARGE TANk CONNECTION (Figure 4)
Step 1. Install two tees in the pump discharge port (see Figure 4). The pipe
Pump Priming
Tee with Plug
or Gauge
Step 2. Run a pipe or reinforced hose from one arm of the first tee to the
From
Step 3. Connect the other end of the discharge tee to your plumbing system.
Well
Step 4. Check the pre-charge of air in the tank with an ordinary tire gauge.
STANDARD TANk CONNECTION (Figure 5)
1864 0205 NEW SWJ
Step 1. Install one tee in the pump discharge port (see Figure 5).
Step 2. Run a pipe from the pump discharge port to the inlet port of your
Step 3. Install a tee in the suction pipe near the pump. Install a reducer
Air Volume
Control
Air Volume
Control Tube
From
Well
size must be at least as large as the discharge port.
port on the pre-charged tank.
Cap the tee with a threaded plug or a pressure gauge.
The pre-charge should be 2 PSI less than the cut-in setting of the
pump's pressure switch. The pre-charge is measured when there
is no water pressure in the tank. Your new pump has a 30/50 PSI
switch, so adjust the tank pre-charge pressure to 28 PSI.
Congratulations! You have just completed the tank connection for
your jet pump.
Please go to Page 7 for electrical hookup.
tank. The pipe size must be at least as large as the discharge port.
bushing down to 1/8" NPT in the tee. Run tubing from the tee to
the port on the AVC mounted on the tank. Seal all joints with PTFE
pipe thread sealant tape. See instructions provided with the tank
and the AVC for details.
Congratulations! You have just completed the tank connection for
your jet pump.
Please go to Page 7 for electrical hookup.
Use only PTFE pipe thread sealant tape for making all
threaded connections to the pump itself. Do not use pipe joint
compounds on plastic pumps: they can react with the plastic in
pump components. Make sure that all pipe joints in the suction
pipe are air tight as well as water tight. If the suction pipe can
suck air, the pump will not be able to pull water from the well.
Sealing Pipe Joints