Electrical Installation; Connecting To A Power Source - Pentair HYDROBOOST Installation And User Manual

Booster pump
Table of Contents

Advertisement

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION.
This booster pump must be installed by a licensed or certified electrician or a qualified pool service professional in
accordance with the current National Electrical Code and all applicable local codes and ordinances. Improper installation
will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to
electrical shock, and may also cause damage to property.
Always disconnect power to the booster pump at the circuit breaker before servicing the pump. Failure to do so could result in death or
serious injury to service professionals, pool users or others due to electric shock.

Connecting to a Power Source

1. Turn off all electrical breakers and
switches before wiring the motor.
2. Connect bonding wire to the bonding lug.
Connect the ground wire to the green
ground screw.
3. Ensure the wiring voltage is 230 VAC
or 115 VAC ± 10%. Permanent motor
damage will occur if wiring voltage does
not match.
4. Use #12 AWG for wiring up to 100 ft.
(30.5 m) and #10 AWG for lengths
longer than 100 ft. (30.5 m). If needed,
use a heavier gauge (larger diameter)
conductor. A heavier gauge will allow the
motor to run cooler and more efficiently.
5. Ensure all electrical connections are
clean and tight.
6. Cut the conductors to the appropriate
length so they do not overlap or touch
when connected to the terminal board.
7. Permanently ground the motor using the
green ground terminal. Use #12 AWG
for wiring up to 100 ft. (30.5 m) and #10
AWG for lengths longer than 100 ft. (30.5
m). Use the correct conductor size and
type specified by the National Electrical
Code. Ensure the ground conductor is
connected to an electrical service ground.

ELECTRICAL INSTALLATION

8. Bond the motor to the pool structure in
accordance with the National Electric
Code. A solid copper bonding conductor
not smaller than 8 AWG is required.
9. Connect the solid copper bonding
conductor on the motor to all metal parts
of the swimming pool, spa, or hot tub
structure and to all electrical equipment,
metal conduit, and metal piping within
5 ft. (1.5 m) of the inside walls of the
swimming pool, spa, or hot tub. For
Canada a 6 AWG or larger copper
bonding conductor is required.
HYDROBOOST™ Booster Pump Installation and User' s Guide