The IntelliFlo
Variable Speed Pump can be controlled
®
by a SunTouch system via the RS-485 communication
cable.
1. Unlatch the front door of the SunTouch system
power center and open the door.
2. Loosen the retaining screw on front panel. Open
the hinged front panel to access the electronics
compartment.
3. Route the two conductor cables up through the
power center grommet opening located on the
left side, and up through the low voltage raceway
to the motherboard.
COM PORT
RS-485 Communication
Cable (P/N 350122
230 VAC Power to Pump
4. Strip back the cable conductors 6 mm (1/4").
Insert the wires into the screw terminals
(provided). Secure the wires with the screws. Be
sure to match the color coding of the wires;
YELLOW to YELLOW and GREEN to GREEN.
5. Insert the connector on the COMPORT (J11)
screw terminal on the SunTouch system circuit
board.
6. Close the control panel and secure it with the
retaining screw.
7. Close the front door. Fasten the spring latch.
GAS
HEATER
RESET
Pump
Drive
INTELLIFLO
Variable Speed Pump Installation and User's Guide
®
19