Connecting To An Automation System; Communication Center - Pentair INTELLIFLO Installation And User Manual

Variable speed pump
Table of Contents

Advertisement

Use the RS-485 communications cable to remotely
control the IntelliFlo
Variable Speed Pump from an
®
IntelliComm communication center. The IntelliComm
system provides four (4) pairs of input terminal
connections. These inputs are actuated by either 15
- 240 VAC or 15 - 100 VDC. Use the device inputs, to
control the programmed pump speeds.
For the pump to accept commands from the
IntelliComm system, the pump must be in the
"Running Schedules" mode (LED above Start/Stop
button is on). If more than one input is active, the
highest number will be communicated to the pump.
The IntelliComm system will always communicate to
pump using ADDRESS #1.
If programs 1 and 2 are activated, program 2 will
run, regardless of the assigned speed (RPM). The
higher program number will always take priority.
External Control is for programming speeds that will
run when the IntelliComm communication center
controller sends it a command.
For example, Terminal 3 and 4 in IntelliComm
system will correspond to External Control Program
#1. (5 and 6 to Ext Ctrl #2). Use the External Control
feature to program the IntelliComm communication
center.
The pump can be controlled by an EasyTouch or
IntelliTouch system via the RS-485 communication
cable. The EasyTouch and/or IntelliTouch control
system starts, stops and controls the speed of the
pump.
EasyTouch and/or IntelliTouch systems rewrite the
pump memory when a command is given. This can
take several seconds and can cause a delay until the
pump physically responds.
The pump control panel is disabled when
communicating with an EasyTouch and/or IntelliTouch
system.
address is "1" (only address for EasyTouch system).

CONNECTING TO AN AUTOMATION SYSTEM

1-2
3-4
5-6
7-8
9-10
11
12
The default pump
INTELLIFLO
Power
100 - 240
100 mA
Supply
VAC
15 -240
VAC
Program
or
1 mA
1
15 - 100
VDC
15 -240
VAC
Program
or
1 mA
2
15 - 100
VDC
15 -240
VAC
Program
or
1 mA
3
15 - 100
VDC
15 -240
VAC
Program
or
1 mA
4
15 - 100
VDC
RS-485
+ Data:
-5 to +5
5 mA
Yellow
VDC
- Data:
Green
Ground
IntelliComm Communication Center
Variable Speed Pump Installation and User's Guide
®
17
1 Input
50/60 Hz
1 Input
50/60 Hz
1 Input
50/60 Hz
1 Input
50/60 Hz
1 Input
50/60 Hz
1 Output
N/A