Operation
Baud rate
(Cond 3400i)
42
4.6

Configuration

You can adapt the measuring instrument to your individual requirements. To
do this, the following parameters can be changed (the status on delivery is
marked in bold):
Baud rate
Calibration interval (Int 3)
AutoRange ARng
Reference temperature
Display of the measured val-
ue as conductivity or specific
resistance
Date/time
Note
You can leave the configuration menu at any time with <M> . The parameters
that have already been changed are stored.
1
Switch off the measuring instrument.
2
Press the <M> key and hold it down.
3
Press the <ON/OFF> key.
The display test appears briefly on the display. The measuring instru-
ment then switches automatically to the setting of the baud rate.
UpH
O
TDS
S
n
t
1
2
8
4
0
Time
Baud
Day.Month No.
Year
Ident
Tref25
Tref20
AutoCal DIN
LoBat
nLF
AutoCal TEC
Lin
Cal
4
Select the required Baud rate with <▲> <▼>.
5
Confirm with <RUN/ENTER>. Int 3 appears on the display.
1200, 2400, 4800, 9600
1 ... 180 ... 999 d
On or off
– 25 °C (TREF25)
– 20 °C (TREF20)
S/cm or MΩ
Any
Sal
mV/pH
% mg/l
m
S/
cm
M
cm
mbar
1/
cm
Sal
0
°
C
/
%
K
TP
°
F
Auto
Store
ARng
AR
RCL
Cond 3300i/3400i