Description of device parameters
Factory setting
Reset user switchpoints
Navigation
Note
Description
Selection
Factory setting
Switch point value (coverage), Output 1/2 (SP1/SP2), Output 1/2 (FL1/FL2)
Switchback point value (coverage), Output 1/2 (rP1/rP2), Output 1/2 (FH1/FH2)
Navigation
Note
42
Standard
Parameter → Application → Reset user switchpoints
This parameter is visible only if the User option is selected
in the Active Switchpoint parameter.
After selecting an output, switch point OU1 or OU2, the
switch output and its associated value are reset to the
factory setting.
• False
• switchpoints OU1
• switchpoints OU2
False
Parameter → Application → Switch point value, Output 1/2
(SP1/SP2)
Parameter → Application → Switchback point value, Output
1/2 (rP1/rP2)
The switching sensitivity of the sensor is set using the
SP1/rP1 or SP2/rP2 parameters. Since the parameter
settings depend on one another, the parameters are
described all together.
• SP1 = switch point 1
• SP2 = switch point 2
• rP1 = switchback point 1
• rP2 = switchback point 2
• FL1 = lower value of window 1
• FL2 = lower value of window 2
• FH1 = upper value of window 1
• FH2 = upper value of window 2
Liquiphant FTL31 IO-Link