Endress+Hauser Liquiphant FTL31 IO-Link Operating Instructions Manual page 25

Point level switch for liquids
Hide thumbs Also See for Liquiphant FTL31 IO-Link:
Table of Contents

Advertisement

Liquiphant FTL31 IO-Link
Designation
ISDU (dec)
ISDU (hex)
Device search
69
0x0045
Sensor check
70
0x0046
Active switchpoints
(OU1)
64
0x0040
Reset user
switchpoints
65
0x0041
Switch point value,
Output 1 (SP1/FH1)
71
0x0047
Switchback point
value, Output 1 (rP1/
FL1)
72
0x0048
Switching delay time,
Output 1 (dS1)
81
0x0051
Switchback delay
time, Output 1 (dR1)
82
0x0052
Output 1 (OU1)
85
0x0055
Output 1 (OU1)
101
0x0065
Active switchpoints
(OU2)
77
0x004D
Endress+Hauser
Size (byte)
Access Default
Data type
value
1
r/w
0~off
UInt8
1
-/w
UInt8
1
r/w
0 ~
UInt8
Density
>0.7g/cm³
1
r/w
0 ~ False
UIntegerT
2
r/w
88.0
UInt16
2
r/w
91.0
UInt16
2
r/w
0.5
UInt16
2
r/w
1
UInt16
1
r/w
0~HNO
UInt8
1
r/w
0~HNO
UInt8
1
r/w
0 ~
UInt8
Density
>0.7g/cm
Value range
Offset/
gradient
0 ~ off
0 / 0
1 ~ on
0 / 0
0 ~ Density
>0.7g/cm³
1 ~ Density
>0.5g/cm³
2 ~ User
0 ~ False
1 ~ switchpoints
Ou1
0 / 1
0 / 1
0 / 0.1
0 / 0.1
0 ~ HNO
1 ~ HNC
2 ~ FNO
3 ~ FNC
0 ~ HNO
1 ~ HNC
0 ~ Density
>0.7g/cm³
1 ~ Density
>0.5g/cm³
2 ~ User
System integration
Data
Range
storage
limits
No
0..1
No
0..2
0..1
Yes
45 to 97
Yes
45 to 97
Yes
0.3 to 60
Yes
0.3 to 60
Yes
0..3
Yes
0..1
0..2
25

Advertisement

Table of Contents
loading

Table of Contents