Liquiphant FTL31 IO-Link
Designation
ISDU (dec)
ISDU (hex)
Maximum µC-
Temperature
93
0x005D
Reset µC-
Temperatures
[button]
94
0x005E
Active switchpoints
(OU1)
64
0x0040
Reset user
switchpoints
65
0x0041
9.2.2
IO-Link-specific device data
Designation
ISDU (dec)
ISDU (hex)
Serial number
21
0x0015
Firmware Version
23
0x0017
ProductID
19
0x0013
ProductName
18
0x0012
ProductText
20
0x0014
VendorName
16
0x0010
Endress+Hauser
Size (byte)
Access Default
Data type
value
1
r/-
-128
Int16
1
-/w
0~False
UIntegerT
1
r/w
0 ~
UInt8
Density
>0.7g/cm³
1
r/w
0~False
UIntegerT
Size (byte)
Data type
max. 16
String
max. 64
String
max. 64
String
max. 64
String
max. 64
String
max. 64
String
Value range
Offset/
gradient
°C: 0 / 1
°°F: 32 / 1.8
K: 273.15 /
1
0 ~ False
1 ~ Reset
Temperature
0 ~ Density
>0.7g/cm³
1 ~ Density
>0.5g/cm³
2 ~ User
0 ~ False
1 ~ switchpoints
Ou1
Access
Default value
r/-
r/-
r/-
FTL31 / FTL33
r/-
Liquiphant
r/-
Vibronic point level switch
r/-
Endress+Hauser
System integration
Data
Range
storage
limits
No
−32768 ..
32767
0..1
0..2
0..1