ELEcTrIcAL cONNEcTION

5 Electrical connection
DANGEr
NOTICE

5.1 connection of the brake

NOTICE
If no suitable DC voltage is available for DC 105 V, or DC 205 V, the following KEB ac-
cessories can be used:
The brake COMBINORM Type B is delivered with factory-preassembled connecting ca-
bles:
cOMBINOrM Type B
Strand cross-sections in mm
Strand length standard in mm
Table 6:
Electrical voltage at brake and motor !
Danger to life due to electric shock !
► When carrying out any work on the brake, switch off the supply volt-
age and secure it against switching on.
Voltage peaks when switching off!
► Install protective circuit for brake and control.
► The protective circuit extends the connection times.
Destruction of the brake in case of incorrect voltage supply
► The brake is operated with DC voltage.
► Read the rated voltage from the magnet marking of the brake.
► Compare with existing voltage source.
► The maximum input voltage U
► Only connect if the values match.
Half and full-wave rectifier (COMBITRON 91)
Fast acting rectifier (COMBITRON 98)
2
Connection of the brake
must not be exceeded.
in
01...06
0.25
≈ 400
07...12
0.75
33