Start-Up; Inspections Prior To Start-Up Of The Brake; Visual Inspection; Load-Free Testing - KEB COMBINORM B Instructions For Use Manual

Table of Contents

Advertisement

INSPEcTIONS PrIOr TO STArT-UP Of THE BrAKE

6 Start-up

6.1 Inspections prior to start-up of the brake

6.1.1 Visual inspection

6.1.2 Load-free testing

NOTICE

6.1.3 run in of the brake

NOTICE
Notes on running-in process:
NOTICE
34
Do connection and rated voltage (magnet marking) agree?
Are external damages visible?
Are there impurities in the functional area or foreign bodies in the air gap of the
brake?
Ensure that the brake is unloaded.
Release/close the brake by switching the voltage supply.
Damage due to non-observance !
► Do not put into operation if one of the tests is not OK.
Damage due to insufficient rated braking torque !
► The rated braking torque is only reached after the brake has run in.
Do not energize magnets.
Stop the drive / motor.
Check the torque.
If the torque is not reached, the cycle must be repeated.
Lower braking torque than holding brake !
► If the brake is only used as a holding brake without dynamic load,
the braking torque may drop. A new run in (refreshment) must be
done within the scope of maintenance.