First Alert FA1600C
Connection Instructions:
1. Connect the 12VDC on the CellComSLCF to terminals 11 and 12
on the host panel.
2. Connect the phone line from TIP and RING on the CellComSLCF
to the Main Phone Jack on the host panel.
3. Cut the blue jumper on the host panel.
4. Follow these programming steps:
1. *30 Main dialer. Default is 0 changed that to 1 for Touch
Tone.
2. *42 Dial tone pause 0=5 seconds
3. *43 Dial tone detection was a 0 which is pause, then dial.
Changed that to a 1=wait for true dial tone.
4. *45 Verified the proper format which is 1=Contact ID
KEYPAD PORT #2
5. Normal Central Station programming.
1 2 3 4 5 6 7 8 9
BELL 1
BELL 2
W1
W4
(WHITE)
(WHITE)
BELL OUTPUTS
AUX. RELAY
4
5
6
7
8
9
10
CellComSLCF Cellular Communicator Dialer Capture Application Note
MODEL CellCom
J8
B
R
J9
S3
+12
G
Z1
J4
KEYPAD PORT #1
ZONE 1
ZONE 2
11
12
13
14
15
16
17
18
APPLICA TION NOTE
S1
RESET
S1
S2
LOAD
S2
Z2
Z3
G
Z4+
Z4-
O1
O2
T
R
ZONE 3
ZONE 5
ZONE 6
ZONE 7
19
20
21
22
23
24
25
Must be installed in
conduit and located
in the same room
within 20 feet.
First Alert
FA 1600C
1 2 3 4 5 6 7 8 9
VOLTAGE
J2
TRIGGERS
Cut the W6
(BLUE) Jumper
W6
BLUE
INTERFACE TO 5140DLM
J3
MAIN
ZONE 8
26
27
28
29
30
PHONE JACK
Digital Monitoring Products
7
Need help?