9.7
Side cover R
(1) Remove the two Taptite bind B M4x12 screws.
(2) Release the Hooks A, B, C, and the Hook D in order of arrow A to C, and remove the Side
cover R.
Note:
• Release the Hooks B while pushing them by using a flat-blade screwdriver or similar
tool.
Taptite bind B M4x12
Hooks B
Hooks A
A
Hook D
Taptite bind B M4x12
<Back side>
Hooks C
C
B
Side cover R
Fig. 3-16
(3) Close the Manual feed slot.
3-29