Brother HL-3160CDW Service Manual page 47

Hide thumbs Also See for HL-3160CDW:
Table of Contents

Advertisement

Error message
First line
Print Unable
Turn the power off
08
and then back on
again.
Print Unable
Turn the power off
09
and then back on
again.
Print Unable
Turn the power off
0A
and then back on
again.
Print Unable
Turn the power off
0B
and then back on
again.
Print Unable
Turn the power off
0C
and then back on
again.
Print Unable
Turn the power off
0E
and then back on
again.
Print Unable
Turn the power off
10
and then back on
again.
Print Unable
Turn the power off
1D
and then back on
again.
Print Unable
Turn the power off
1E
and then back on
again.
Second line
An error occurred in the internal
temperature sensor.
Detected irregular power supply
for more than 100 times.
Main PCB detected the fan
failure.
An error occurred in the high-
voltage power supply PCB while
operating.
An error occurred in the high-
voltage power supply PCB
when the machine was in the
ready state.
An error occurred in the density
sensor.
An error occurred during the
high-voltage power supply PCB
ID check.
The registration mark sensor R
is dirty and cannot normally
receive reflected light.
The registration mark sensor L
is dirty and cannot normally
receive reflected light.
A communication error occurred
in the LED ASSY (black).
A communication error occurred
in the LED ASSY (yellow).
A communication error occurred
in the LED ASSY (magenta).
A communication error occurred
in the LED ASSY (cyan).
Main PCB and LED control PCB
cannot access each other.
Cannot read/write in the main
PCB and LED control PCB.
2-28
Description
Error
Refer
codes
to:
0800
2-50
0900
2-51
0A02
2-51
0B01
2-52
0B02
2-52
0C00
2-52
0E00
2-52
1003
2-53
1004
2-53
1D01
2-54
1D02
2-54
1D03
2-54
1D04
2-54
1E01
2-54
1E02
2-54
Confidential