Change of the transfer current setting (Only for Japan models)
< Function >
Dots appeared when hagaki printing is performed can be alleviated by changing the transfer
current setting.
< Operating Procedure >
(1) For models with touch panel
Press the [4], and then the [5] in the initial state of maintenance mode. "USBNo." is
displayed on the LCD.
For models without touch panel
Press the [▲] or [▼] in the initial state of maintenance mode to display "MAINTENANCE
45" on the LCD, and press the [OK]. "USBNo." is displayed on the LCD.
(2) Press the [▲] or [▼] to display "Special Printing" on the LCD, and press the [Mono Start],
[SET] or [OK]. "default" is displayed on the LCD.
(3) Press the [▲] or [▼] to change the setting, and press the [Mono Start], [SET] or [OK].
There are four setting options: "default", "HAGAKI1", "HAGAKI2", and "HAGAKI3". ("*" is
displayed at the end of the currently specified function in the LCD display. The initial value
is "default".)
(4) "Accepted" is displayed on the LCD, and the machine returns to the initial state of
maintenance mode.
(5) Perform hagaki printing again to check if the dot symptom is improved.
(6) If not, repeat the steps (1) to (4) to set an optimum option, and then perform hagaki printing.
Change of ghost reduction setting
< Function >
This function is a mode to reduce the level of ghost when it appears in low temperature and high
humidity environment. If this function is turned ON, however, spots and dirt may appear on print.
LCD
ON
OFF
"*" is displayed at the end of the currently specified function in the LCD display.
< Operating Procedure >
(1) For models with touch panel
Press the [4], and then the [5] in the initial state of maintenance mode. "USBNo." is
displayed on the LCD.
For models without touch panel
Press the [▲] or [▼] in the initial state of maintenance mode to display "MAINTENANCE
45" on the LCD, and press the [OK]. "USBNo." is displayed on the LCD.
(2) Press the [▲] or [▼] to display "Ghost Reduction" and then press the [Mono Start], [SET]
or [OK].
(3) Press the [▲] or [▼] to select "ON" or "OFF", and press the [Mono Start], [SET] or [OK].
(4) "Accepted" is displayed on the LCD, and the machine returns to the initial state of
maintenance mode.
Turn ON the ghost reduction function.
Turn OFF the ghost reduction function. (default)