Switching of timing to execute auto registration
< Function >
Relative displacement between Cyan, Magenta, Yellow, and Black is detected using the
registration mark sensor, and the Auto Registration is executed at the timing when the
displacement value exceeds the stipulated threshold value.
This function is to switch the threshold value which is used as the timing to execute Auto
Registration. The threshold value can be switched in three phases between High, Mid, and
Low.
LCD
Regi Freq=Mid
Regi Freq=High
Regi Freq=Low
"*" is displayed at the end of the currently specified function in the LCD display.
Note:
It can be set regardless of the Auto Registration switching function in the function menu.
Even if this function is switched, it does not affect the timing to execute Auto Registration in
the function menu.
< Operating Procedure >
(1) For models with touch panel
Press the [4], and then the [5] in the initial state of maintenance mode. "USBNo." is
displayed on the LCD.
For models without touch panel
Press the [▲] or [▼] in the initial state of maintenance mode to display
"MAINTENANCE 45" on the LCD, and press the [OK]. "USBNo." is displayed on the
LCD.
(2) Press the [▲] or [▼] to display "Regi Freq" on the LCD, and press the [Mono Start], [SET]
or [OK].
(3) Press the [▲] or [▼] to select "Regi Freq = Mid", "Regi Freq = High" or "Regi Freq = Low"
on the LCD, and press the [Mono Start], [SET] or [OK].
(4) "Accepted" is displayed on the LCD, and the machine returns to the initial state of
maintenance mode.
The frequency to execute Auto Registration is middle. (default)
The frequency to execute Auto Registration is high.
The frequency to execute Auto Registration is low.
5-20