To activate the AC system after the generator has been started, make sure all AC circuit
breakers are in the OFF position. Slide the breaker bar up from the generator breaker and over
the shore power breaker. You can now turn on the generator breaker.
NOTE: The generator has a circuit breaker located beside the generators inverter control unit
within the inboard locker in the port fwd cabin.
SHORE POWER
Prior to plugging in the power lead, ensure the shore power breaker is OFF and all drawing
breakers are in the OFF position. Plug in the shore power lead and ensure the on shore breaker
is switched on. A light should appear beside the onboard shore power breaker. Ensure both
RCD's located on the AC panel are on (these breakers can remain on at all times). Switch ON
the shore power breaker and you are now free to turn on other AC breakers such as air-
conditioning, charger/invertor and 220V GPO's.
NOTE: If the shore power connection does not show power on the breaker panel check the
inline fuse behind the shore power inlet on the transom.
If Lithium batteries are installed an optional second battery charger may be fitted to charge the
start batteries in the event that the start batteries are below the required starting voltage. This
charger can be turned on via the Start Batt Charger breaker on the 220V breaker panel.