CHAPTER 3 OCD CHECK FOR MINICUBE2 AND 78K0 MICROCONTROLLER
No.
Error message and action
7
Incorrect ID code
The input ID code is incorrect.
→ Confirm the ID code written to the target device and re-input the ID code.
8
Log file write error
The specified log file cannot be accessed.
→ Confirm that the folder, path, and file are write-enabled.
9
Test Rom Command(xxH) Error, Monitor Command(xxH) Error
Communication between the target device and MINICUBE2 has failed.
→ The cause may be a problem in the electrical specifications of the cable or the target system, or the USB
driver may not be operating normally.
Confirm the connection and restart Windows on the host machine.
10
Write Memory, Read Memory, Data verify error
The internal RAM cannot be accessed. The target device may be damaged.
→ Exchange the target device.
11
_Flash Env Error, _Flash Get Info Error, _Flash Block Blank Check Error, _Flash Block Erase Error, _Flash Word
Write Error, _Flash Block Verify Error, _Flash Word Read Error, Data Verify Error
An error occurred while writing to the flash memory.
→ The cause may be the security flag setting, so clear the security flag setting via the QBP.
The target device may be damaged, so exchange the target device.
12
Break Timeout, ERROR: SP Break Test, ERROR: Execute Break Test1, ERROR: SFR Access Break Test,
ERROR: Read Access Break Test1, ERROR: Read Access Break Test2, ERROR: Write Access Break Test1,
ERROR: Write Access Break Test2, ERROR: Step Break Test, ERROR: Execute Break Test2
The target device may be damaged, so exchange the target device.