schmersal PSC1 Series Installation Manual page 174

Hide thumbs Also See for PSC1 Series:
Table of Contents

Advertisement

Installation manual
Two-hand button
Switch type
Remark
2 change-over
Two-hand button for
contacts
increased requirement
2 normally open
Monitored two-hand button
contacts
Note: On these input elements there is a fixed pulse assignment that the user cannot change!
Light curtain
Switch type
Remark
2 normally closed
Light curtain for increased
contact
requirement
2 normally closed
Monitored light curtain
contacts time
monitoring
1 normally open
Light curtain for increased
contact + 1 normally
requirement
closed contact
1 normally open
Monitored light curtain
contact + 1 normally
closed contact time
monitored
Operating mode selector switch
Switch type
Remark
2 positions
Monitored operating mode
selector switch
3 positions
Monitored operating mode
selector switch
Safety instructions: On a state change on the switch, it is to be ensured by the SafePLC2
program to be written that the outputs on the module are deactivated (note: standard 60204
part 1 section 9.2.3).
Sensor
Switch type
Remark
1 normally closed
Simple sensor input
contact
1 normally open
Simple sensor input
contact
2 normally closed
Sensor input for increased
contacts
requirement
2 normally closed
Monitored sensor input
contacts time
monitoring
1 normally open
Sensor input for increased
contact + 1 normally
requirement
closed contact
HB-37350-810-01-38F-DE PSC1-C-10 Installation manual V1.1.docx
Version: 38F
Category
categorisation
Type III C PL e
Type III A PL e
Category
categorisation
PL e
PL e
PL e
PL e
Category
categorisation
PL e
PL e
Category
categorisation
PL d
PL d
PL e
PL e
PL e
SIL categorisation
SIL3
SIL1
SIL categorisation
SIL 3
SIL 3
SIL 3
SIL 3
SIL categorisation
SIL 3
SIL 3
SIL categorisation
SIL 2
SIL 2
SIL 3
SIL 3
SIL 3
Page 174 of 177