Example software specification
Seq
Safety function
. no.
1.4
Monitoring V_rope in
relation to V_required
Monitoring of the
difference between main
drive speed and rope drive
for maximum value
1.6
Backstop
Monitoring for return
1.15
Stepwise shutdown 3
Activation of the safety
brake
1.8
Functional standstill
1.9
Direction monitoring
HB-37350-810-01-38F-DE PSC1-C-10 Installation manual V1.1.docx
Version: 38F
PL
Measured
New solution
r
value /sensor
d
Digital
Monitoring using tested function SLS
incremental
+ SAC with comparison of speed
encoder,
ranges / analogue value range =
comparison for diagnostics on the
tacho generator
speed acquisition
sheave
Shutdown 2-channel new (see
below)
d
Mechanical limit
Monitoring using tested function,
switch 22S2
direction monitoring SDI
Digital
incremental
encoder
e
-
Processing of SF in SafePLC2
d
Digital
Standstill monitoring using tested
incremental
function SOS
encoder
e
Digital
Monitoring using tested function,
incremental
direction monitoring SDI
encoder,
Input/activation
Continuous
Reset:
Reset button
EMERGENCY
(auxiliary contact
28K4 – inspection
movement)
Reset:
Reset button
SF 1.2
SF 1.3.2
SF 1.7
SF 1.8
Controller disable
OR
Set service brake
28K1 = FORWARD
28K2 = BACK
= safe < signals
from "Frey"
controller
Page 158 of 177
Response/output
Operating stop
SF 1.3.1
Operating stop
SF 1.3.1
Set safety brake
SF 1.15/
Set safety brake
Operating stop
SF 1.3.1