Installation manual
Safety function:
Running gear shutdown
Running gear shutdown and deactivation of brakes
Running gear shutdowns
The running gear is shutdown via two outputs (EAA1.5 ID 257 and 1.6 ID 261).
The brakes are shutdown via two outputs (EAA1.3 ID 253 and 1.4 ID 249).
A message is sent to the PLC via bit 40 (ID 600).
If there is an emergency stop, the shutdown is implemented immediately.
Hoist
Safety function
Emergency stop button inputs and shutdown outputs
Emergency stop head controller
Dual-channel emergency stop with pulse monitoring.
If an emergency stop is triggered on the higher-level controller, this emergency stop can be
bypassed using 'Bypass safety' enable.
Emergency stop button head controller
Emergency stop contacts from the emergency stop relay with pulses from the PSC1