Hot-Swap Drive Replacement; Remove A Hot-Swap Drive - Lenovo ThinkSystem SR665 V3 User Manual

Hide thumbs Also See for ThinkSystem SR665 V3:
Table of Contents

Advertisement

Hot-swap drive replacement

Follow instructions in this section to remove and install a hot-swap drive. You can remove or install a hot-
swap drive without turning off the server, which helps you avoid significant interruption to the operation of
the system.
"Remove a hot-swap drive" on page 77
"Install a hot-swap drive" on page 78
Notes:
• The term "hot-swap drive" refers to all the supported types of hot-swap hard disk drives, hot-swap solid-
state drives, and hot-swap NVMe drives.
• Use any documentation that comes with the drive and follow those instructions in addition to the
instructions in this topic. Ensure that you have all the cables and other equipment that are specified in the
documentation that comes with the drive.
• The electromagnetic interference (EMI) integrity and cooling of the server are protected by having all drive
bays covered or occupied. The vacant bays are either covered by an EMI-protective panel or occupied by
drive fillers. When installing a drive, save the removed drive filler in case that you later remove the drive
and need the drive filler to cover the place.
• To avoid damage to the drive connectors, ensure that the top cover is in place and fully closed whenever
you install or remove a drive.

Remove a hot-swap drive

Follow instructions in this section to remove a hot-swap drive.
About this task
Attention:
• Read
"Installation Guidelines" on page 39
work safely.
• Before you remove or make changes to drives, drive controllers (including controllers that are integrated
on the system board assembly), drive backplanes or drive cables, back up all important data that is stored
on drives.
• Before you remove any component of a RAID array (drive, RAID card, etc.), back up all RAID configuration
information.
• If one or more NVMe solid-state drives are to be removed, it is recommended to disable them beforehand
via the operating system.
• To ensure that there is adequate system cooling, do not operate the server for more than two minutes
without either a drive or a drive filler installed in each bay.
Note: Make sure you have the drive bay fillers available if some drive bays will be left empty after the
removal.
Watch the procedure
A video of this procedure is available at YouTube:
DR4X1YAcp9wFKhwj_tLQ5Y
Procedure
Step 1.
If the security bezel is installed, remove it first. See
and
"Safety inspection checklist" on page 40
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
.
"Remove the security bezel" on page
.
Chapter 5
Hardware replacement procedures
to ensure that you
137.
77

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d9a7d9b

Table of Contents