Installation Requirements

The KWS500 has specific connection requirements and rules for installation. Following these
guidelines is necessary for a successful installation.
Connection requirements
The KWS500 requires cabling from the host PBX distribution frame to the mounting location of
the KWS500. Cabling provided should be 24 gauge
specifications of the host PBX.
The KWS500 requires one connection to an analog station port
frame for each KIRK Handset. Using the Cat. 3 cabling, analog station ports are wired directly
from the host PBX distribution frame to the termination block in the KWS500.
The KWS500 requires a local power connection (standard 120V AC). A dedicated, conditioned
power source within six feet of the mounting location is recommended.
At least one KIRK Handset must be charged and available to establish a wireless connection with
the system. This is necessary for initial programming of the system. (More in-depth
Copper wire with a thickness of 0.02" (0.51 mm), commonly used for telephone wiring and other
1
electronics applications such as speaker wire and computer network cabling.
Pair of connectors in a termination block that are dedicated to a particular analog station
2
(telephone extension) on the PBX system. It is used to transmit analog signals, as opposed to digital
signals.
Mount the KWS500 vertically, at least 6
feet high
Fig. 3 Mounted KWS500
Cat. 3 cable. Distance is limited by the
1
KIRK Wireless Server 500 User Guide
on the host PBX distribution
2
15