Installation

Installation of this equipment involves potentially
hazardous procedures. Only trained and qualified
personnel who have read and who understand the
information in this manual should install this
equipment.
To avoid injury from fire, explosion, or electric
shock, all electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.

Mount the Pump

The pump may be very heavy (see Technical
Specifications, starting on page 50, for specific
weights). Use at least two straps and appropriate
lifting equipment or have two people lift the pump.
Do not use the outlet manifold alone to lift the pump.
1. Ensure that the mounting surface is level.
2. Ensure that the mounting surface and mounting
hardware is strong enough to support the weight of
the pump, fluid lines, accessories, and fluid, as well
as the stress caused during operation.
3. For all mountings, be sure the pump is secured with
fasteners through the mounting holes on the base.
See F
. 5. See Dimensions, starting on page 44.
IG
NOTE: For ease of operation and service, mount
the pump so the control knob (K), LED indicator
(CC), I/O port/cable (BB), and fluid inlet and outlet
ports (B, C) are easily accessible.
NOTICE
To avoid pump damage, mount the pump to the
mounting location using fasteners though each hole
of the feet. See F
. 5.
IG
3A8572B
F
. 5: Mounting Holes
IG

Connect Fluid Lines

Use conductive, flexible fluid lines for fluid supply (F)
and fluid outlet (J) lines.
NOTE: For proper priming, ensure the fluid outlet
port (C) is mounted higher than the fluid inlet port (B).
See F
. 3 and F
. 4.
IG
IG
1. Install conductive, flexible fluid lines (F and J).
2. Install a fluid drain valve (G) near the fluid outlet.
See F
. 3 and F
. 4.
IG
IG
A fluid drain valve (G) is required to relieve pressure
in the fluid outlet line. The drain valve reduces the risk
of serious injury, including splashing in the eyes or on
the skin, when relieving pressure.
3. Install a fluid shutoff valve (H) in the fluid outlet line
(J) downstream from the fluid drain valve (G).
NOTE: Install the equipment as close as possible to the
material source. See Technical Specifications,
starting on page 50, for maximum suction lift.
NOTICE
The pump can be damaged if flexible fluid lines are
not used. If hard-plumbed fluid lines are used in the
system, use a short length of conductive, flexible
fluid line to connect to the pump.