D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor. D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
Page 3
D Use only Graco approved hoses. Do not remove the spring guard that is used to help protect the hose from rupture caused by kinks or bends near the couplings.
Page 4
WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing/dispensing immediately.
5. Fluid supply container: follow your local code. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor. If you 6. Object being sprayed: follow your local code.
Page 6
Setup D The pump air regulator (H) controls pump speed Components and Accessories (continued) and outlet pressure by adjusting the air pressure to Refer to Fig. 2. the pump. Locate the regulator close to the pump, but upstream from the pump air bleed valve (G). WARNING D The air manifold (D) has a swivel air inlet.
Page 7
Setup MAIN AIR LINE Pump 19 Liter (5 Gallon) Air-Powered Ram Wiper Plate Air Manifold Pump Runaway Valve (location show Air Line Lubricator (location shown) G Pump Bleed-Type Air Valve (required Pump Air Regulator Air Line Filter Bleed-Type Master Air Valve (for acc Fluid Drain Valve (required) M Electrically Conductive Fluid Whip H Airless Spray Gun or Dispensing Va...
Operation Pressure Relief Procedure Starting and Adjusting the Ram 1. Refer to Fig. 3. Close all air regulators and air WARNING valves. SKIN INJECTION HAZARD The system pressure must be manually 2. Open the red-handled main air bleed valve (V) and relieved to prevent the system from set the ram air regulator (T) to 2.8 bar, 0.28 MPa starting or spraying accidentally.
Page 10
Operation Starting and Adjusting the Pump 2. Before raising the wiper plate, locate the pushbut- ton on the air release valve (X). 1. Be sure the pump air regulator (H) is closed. Then set the ram air regulator (T) to about 2.1 bar, 0.21 3.
Page 11
Operation Pump Pump Air Regulator JJ Pump Bleeder Valve (out of view) Ram Air Regulator KK Wiper Plate Vent Handle Wiper Plate Ram Director Valve LL Vent Hole G Pump Air Bleed Valve Air Release Valve (required, for pump) 0621B Fig.
Parts Part No. 231047, Series B 25:1 Ratio Bulldog Pump, with standard air motor Includes items 1–34, 45, 46 Part No. 222529, Series B (shown) Detail of Air Controls for Model 222529 only 25:1 Ratio Severe-Duty Bulldog Pump, with standard air motor Includes items 1–52...
Page 13
25:1 Ratio Bulldog Pump, with standard air motor Includes items 1–34, 45, 46 Part No. 222529, Series B (shown) 25:1 Ratio Severe-Duty Bulldog Pump, with standard air motor Includes items 1–52 Part No. 223987, Series A 25:1 Ratio Severe-Duty Bulldog Pump, with quiet air motor Includes items 1–34, 45, 46...
Dimensions 14.2 mm (0.56 in.) Diameter Holes 0621B Pump Weight Model (Raised) (Lowered) 231047 1632 mm 1201 mm 279 mm 356 mm 356 mm 432 mm 546 mm 83 kg 64.25 in. (47.25 in.) (11 in.) (14 in.) (14 in.) (17 in.) (21.5 in.) (182 lb)
Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. As purchaser’s sole remedy for breach of this warranty, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment proven defective.