RAID battery backup status
Other sensors
36
Installation and User's Guide
Monitors the battery backup unit on the RAID controller.
From the WebGUI, click STATUS → System → RAID Battery Backup
Status.
From the command line, enter show raid-battery-backup.
Provides truth values for the intrusion switch, power supply modules,
batteries, and the hard disks.
v A value of true indicates that the condition exists.
v A value of false indicates that the conditions does not exist.
For the intrusion switch, the value indicates whether it has been tripped.
v For each power supply, the value indicates the condition:
– Output Failure
– Present
v For each hard disk in the array and the battery, the values indicates the
state:
– Fault
– Present
Note: The hard disk drive modules are not hot-swappable. Hot
swapping the modules will cause your system to crash, and could
possibly damage your appliance.
v From the WebGUI, click STATUS → System → Other Sensors.
v From the command line, enter show sensors-other.
Need help?
Do you have a question about the WebSphere DataPower 7198 and is the answer not in the manual?