Viewing Status Providers For Sensors - IBM WebSphere DataPower 7198 Installation And User Manual

Table of Contents

Advertisement

5. To select a test to run, enter its number at the Select action prompt.
Note: The diagnostics user interface can differ depending on your firmware
After completing a test, the diagnostic self-test produces one of the following
results:
v PASS
v FAIL
v SKIP
v RUNNING
v SKIP
v n/a

Viewing status providers for sensors

The DataPower appliance provides the following sensors status providers:
Fan speed sensors
Temperature sensors
Voltage sensors
DataPower Hardware Diagnostics Tool Version 1.0
(C) Copyright 2011 - IBM Corporation
Main Menu:
1. Inventory
2. BMC/Sensors
3. Network
4. Memory
5. Disks
0. Exit Diagnostics
Select action>
release.
Provides the measured speed in revolutions per minute (RPM) for each of
the fans in each fan module.
From the WebGUI, click STATUS → System → Fan Sensors.
From the command line, enter show sensors-fans.
Provides the measured temperature in degrees Celsius for internal
components:
v Temperature of each of the two internal CPU components
v Temperature of each of the two internal inlet air temperatures
v Temperature of each of the two internal system components
From the WebGUI, click STATUS → System → Temperature Sensors.
From the command line, enter show sensors-temperature.
Provides the measured voltage for the internal components.
From the WebGUI, click STATUS → System → Voltage Sensors. The voltage
is measured in volts.
From the command line, enter show sensors-voltage. The voltage is
measured in millivolts.
n/a
n/a
n/a
n/a
n/a
Chapter 5. Diagnosing your appliance
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Websphere datapower 7199

Table of Contents