Connecting
5.1
Safety notes and conditions
Safety notes
To ensure safe operation of this device, it must be properly installed and commissioned by
qualified personnel in adherence to the warning notices. This includes both the general
safety regulations for working on high voltage systems (e.g. DIN VDE) and the regulations
relating to proper use of tools and the use of personal protective equipment (goggles,
protective gloves etc.).
Caution - the power supply is to be shut off before opening the device. Non-compliance can
result in death, severe physical injury and/or significant damage.
Note
All connecting leads inside the device should be kept short.
To ensure the degree of protection according to IP65 for the device, only the permissible
cable diameters may be used.
Required tools
You will need the following screwdrivers:
● To open the housing: Screwdriver for M4 slotted screws
● For connecting terminals: Screwdriver for M2.5 slotted screws
● Shielding connections: T10 screwdriver for M3 torx-slotted screws
● Earthing: T20 screwdriver for M4 torx-slotted screws
SITRANS DA400 for oscillating positive displacement pumps
Operating Instructions, 09/2008, A5E00841120-03
WARNING
5
27