Siemens 7MJ2000-1A 00 Series Operating Instructions Manual page 92

Process monitoring for oscillating positive displacement pumps
Table of Contents

Advertisement

PROFIBUS DP
11.1 Overview
3. Module "Status: 4 Sound / 4 AI / Binary"
Table 11- 3
Byte no.
0
1
2
3
4
5
6
7
8 to 15
4. Module "4 SoundAmpl+Status"
Table 11- 4
Byte no.
0 to 3
4
5 to 8
9
10 to 13
14
15 to 18
19
5. Module "4 SoundAmpl+St/Binary Status"
Table 11- 5
Byte no.
0 to 3
4
5 to 8
9
10 to 13
14
15 to 18
19
20 to 27
92
Config Byte: 0x17,0x17 -> 16 byte input
Signal name
Sensor 1 status
Sensor 2 status
Sensor 3 status
Sensor 4 status
Universal input 1 status
Universal input 2 status
Universal input 4 status
Universal input 5 status
8 byte binary status messages
Config Bytes: 0x94,0x94,0x94,0x94 -> 20 byte input
Signal name
Sensor 1 measured value
Sensor 1 status
Sensor 2 measured value
Sensor 2 status
Sensor 3 measured value
Sensor 3 status
Sensor 4 measured value
Sensor 4 status
Config Bytes: 0x94,0x94,0x94,0x94,0x17 -> 28 byte input
Signal name
Sensor 1 measured value
Sensor 1 status
Sensor 2 measured value
Sensor 2 status
Sensor 3 measured value
Sensor 3 status
Sensor 4 measured value
Sensor 4 status
8 byte binary status messages, bit coded
SITRANS DA400 for oscillating positive displacement pumps
Operating Instructions, 09/2008, A5E00841120-03