Sensor Operation - Siemens 7MJ2000-1A 00 Series Operating Instructions Manual

Process monitoring for oscillating positive displacement pumps
Table of Contents

Advertisement

Description
3.4 Mode of operation
3.4.3

Sensor operation

The acoustic emission sensor works on the piezoelectric principle. The acoustic emission is
injected into the sensor via the sensor base (mounting surface) and inside it is converted into
an electrical voltage by a piezoceramic element. This is amplified in the sensor and
transmitted via the cable.
The sensor frequency range lies in the ultrasonic range (>20 kHz). The sensor is non-
directional, i.e. the angle at which the sound wave is incident on the sensor base is not
important.
20
SITRANS DA400 for oscillating positive displacement pumps
Operating Instructions, 09/2008, A5E00841120-03