System Chart - Nakanishi COMBOX-NET.EIP Operation Manual

Network interface
Table of Contents

Advertisement

7 SYSTEM CHART

 The following controllers can be connected to the COMBOX-NET.EIP.
‒ E3000
‒ E4000
‒ E2280
‒ iSpeed3
‒ iSpeed5
 One controller made by NAKANISHI can be installed on a COMBOX-NET.EIP.
 A digital and analog (0 to 5 V) sensor are each installed on each of the two channels.
 When connecting by EtherNet/IP, configure the network in a star topology.
 COMBOX-NET.EIPs cannot be connected to each other.
 Devices such as proximity sensors and fiber sensors that support open collector output can be installed as digital
sensors, and the ON-OFF status of the sensors is transferred to the scanner.
 Devices such as thermometers, flowmeters and pressure gauges that output analog voltage (0 to 5 V) can be installed
as analog sensors, and the voltage data (0 to 5000) of these devices is transferred to the scanner.
*1 For details on controller connections, refer to the Operation Manual for the respective model of controller.
*2 Use a noise filter to reduce the influence of noise from the power source.
NOTICE
50

Advertisement

Table of Contents
loading

Related Products for Nakanishi COMBOX-NET.EIP

This manual is also suitable for:

Ne339

Table of Contents