11–1 Input Data
Input addresses are annotated in word units. n is the initial address set by the scanner.
<Model Name>
Address
Item Code
Data
Model Name
bit-0
E3000
bit-1
E4000
bit-2
E2280
bit-3
iSpeed3
bit-4
iSpeed5
to
to
bit-15
<Parameters>
Address
Item Code
Data
Output is OFF when an error
bit-0
occurs, and output is ON when a
warning occurs.
Output is ON when an error
bit-1
occurs, and output is ON when a
warning occurs.
bit-2
Error code, warning code
Analog: Set motor speed at
bit-3
SPD_SET.
Pulse: Set motor speed at
bit-4
CNT_IN/UD_IN.
Speed point: Set motor speed at
bit-5
SEL0/SEL1.
bit-6
Motor Speed Characteristics*2
EM-3030T selection (only when
bit-7
E3000 controller is in use)
to
bit-15
*1 Some parameter P1 error output logic cannot be set to error codes depending on the controller.
*2 Parameters must be set on the controller to match the motor used.
Match the setting of bit-6 to the setting of Motor Speed Control Voltage/DC+10V Signal Method.
*3 E4000, iSpeed3 and iSpeed5 parameters need not be set on the controller.
Set the motor speed characteristics to match the motor used by referring to the "SPD_SET" table.
Set only the bits corresponding to the model of connected controller to ON.
A model setting error occurs if this item is not set to ON.
A model setting error also occurs if two or more bits are selected or a bit not set with the
model name is set to ON.
Contents
n+0x10
TYPE
Remarks
n+0x11
PARAM
Remarks
Select either of these two
settings.
Match the setting on the
controller. A parameter setting
error occurs if this item is not
selected.
Select either of these two
settings.
Match the setting on the
controller. A parameter setting
error occurs if this item is not
selected.
Select according to the motor
used.
(Refer to the "Motor Speed
Setting" table given later.)
ON when EM-3030T is in use
to
66
Controller parameters
All models: P1
Setting of Error Output Mode
E2280: P7
Other models: P5
Selection of Motor Speed
Control Voltage/DC+10V Signal
Method
E3000: P8
E2280: PA
Not set
*1
*3