11–4 Data/Ready Details
<Data/Ready Details>
DATA_READY
Set Model Abnormality
Set Parameter Abnormality
Set Control Abnormality
Set Speed Abnormality
COMBOX Power Source
Abnormality
Controller Connection
Abnormality
 "START" operation is disabled and the motor does not operate when the above error occurs. Check the error type,
and remove its cause.
・None of model name (bit-0 to 4) is set or two or more are set.
・Unused parts (bit-5 to 15) are set.
・None of PARAM (bit-0 to 2) is set or two or more are set.
・None of PARAM (bit-3 to 5) is set or two or more are set.
・CTRL (bit-7) is set with the model name set to one of E3000/E4000/iSpeed5.
・A set speed abnormality has occurred.
・CTRL (bit-4, 5) is set when the motor speed setting is other than pulse.
・CTRL (bit-10, 11) is set when the motor speed setting is other than speed point.
(excluding E3000)
A value outside the allowable range is set for the motor speed control.
The sensor power source (PW2) is down.
・The controller is not connected normally.
・The power source of the controller is not ON.
NOTICE
Occurrence conditions