DC Power Supply LEDs on an ACX5000 Router

Table 15: DC Power Supply LEDs on an ACX5000 Router

Name
Color
Input
Unlit
Green
Output
Unlit
Green
Fault
Amber
Copyright © 2015, Juniper Networks, Inc.
Connecting AC Power to an ACX5000 Router on page 114
Figure 15 on page 31
shows the location of the LEDs on the DC power supply.

Figure 15: DC Power Supply Faceplate on an ACX5000 Router

1—
Input LED
2—Output LED
CAUTION:
The V+ terminals are shunted internally together, as are the V–
terminals. The same polarity terminal can be wired together from the same
source to provide an additional current path in a higher power chassis. Do
not connect the terminals to different sources.
Table 15 on page 31
describes the LEDs on the DC power supplies.
State
Off
On steadily
Off
On steadily
On steadily
Chapter 2: Chassis Components and Descriptions
3—
Fault LED
Description
The power supply is disconnected from power,
or power is not coming into the power supply.
Power is coming into the power supply.
The power supply is disconnected from power,
or the power supply is not sending out power
correctly.
The power supply is sending out power correctly.
An error has been detected in the power supply.
Replace the power supply as soon as possible.
To maintain proper airflow through the chassis,
leave the power supply installed in the chassis
until you are ready to replace it.