2.2.3 ATEX / IECEx System Configuration

Together with the standard pump head and controllers an ATEX / IECEx certified motor allows installation of
motor and pump head within an Ex classified area (see Figure 5). The ATEX / IECEx motor (Pos. 2b in in
Table 2) comes delivered with special connectors and according extension cables (Pos. 5a and 5b in Table
3). One option to lead the cables outside of the classified area is an Ex certified cable sealing system as
listed in Table 4 (see Pos. 8) and shown in Figure 2.
Fluid In
Fluid Out
Ex Classified Location
Chemical Resistance and IP-67 Space
Figure 5: System configuration for ATEX / IECEx applications

2.3 General Environmental Conditions

Usage
Altitude
Operating ambient temperature
Storage ambient temperature
(Extremes for Transportation)
Operating humidity range (relative humidity)
Storage humidity range (relative humidity)
(Extremes for Transportation)
Normal storage conditions
AC supply fluctuations
Transient over-voltages typically present on
the mains supply
Pollution degree
PL-4021-00, Rev02, DCO# 15-235
1
Pump Head
Motor Sensor Cable
Motor
(ATEX/IECEx)
Motor Power Cable
2b
Table 5: Environmental conditions for pump system
Cabinet Boundary for
Ex classified Area
Adaptor/Extension
Cable for Sensors
Adaptor/Extension
Cable for Power
9
5a
5b
Ex conform cable sealing system
Indoor
(motor with pump head can be placed outdoor)
Up to 2000 m
0 to 40 °C
-20 to 80 °C
15 – 95% (non-condensing)
15 – 95% (non-condensing)
Ambient temp.: 20 to 30 °C
Relative humidity: 50% (non-condensing)
 10% of nominal voltage
Surge immunity according to EN 61000-4-5
2
User Manual for BPS-2000
www.levitronix.com
All
3
Controller
Types
3 x AC 200-240V or
1 x AC 200-240V