CLI Command Set
The CLI uses the following set of commands:
•
cable – Specifies the length of cable for optimal signal quality. See page 25.
•
enclosure – Displays full information on the VessJBOD enclosure and its
components. See page 26.
•
factorydefault – Restores factory default settings. See page 29.
•
help – Use alone to see the list of commands. Use with a command to see a
list of options. Examples: enclosure -help or enclosure -h. See page 30.
•
link – Displays the current status of the PHYs (links), error counter,
expander and attached SAS addresses. See page 30.
•
route – Displays addresses of components through a downstream
(expansion) connection. See page 34.
•
uptime – Displays the number of days, hours, minutes and seconds since
the firmware was loaded (since the VessJBOD was started or restarted). See
page 35.
•
vpdr – Displays vital product data on field replaceable units. See page 36.
•
? – Use alone to see the list of commands. Use with a command to see a list
of options. Example: enclosure -? See page 36.
Cable Command
The Cable command displays the current cable length settings for the two SAS
ports. The I/O module supports cables from 1 to 8 meters in length.
Figure 4. VessJBOD SAS ports
CN#1 refers to the SAS IN port and CN#2 refers to the SAS OUT port on the I/O
module. See above, Figure 4.
Command options are NOT case-sensitive.
CN#1 or SAS IN port
Note
CN#2 or SAS OUT port
25
Chapter 3: Management