Enclosure Command - Promise Technology VessJBOD 1000 Series Product Manual

Table of Contents

Advertisement

VessJBOD 1000 Series Product Manual
To view the current settings:
At the cli> prompt, type cable and press Enter.
The system returns:
CN#1 Cable Length = 1 meter
CN#2 Cable Length = 1 meter
To set Expansion connector CN2 for a 3-meter cable:
At the cli> prompt, type cable -a mod -s "cn2=3" and press Enter.
The system returns:
Cable length of connector 2 is set to 3 meter

Enclosure Command

The Enclosure command:
Enables you to reboot the VessJBOD enclosure (below)
Displays information about the VessJBOD enclosure (page 27)
Enables you to make enclosure settings (page 28)
Rebooting the Controller
You can reboot just the controller (I/O module). This action might be needed to
help with setting changes on the VessJBOD.
To reboot the only the controller:
1.
Verify that no data I/O activity is in progress.
2.
At the cli> prompt, type enclosure -a mod -s "reboot=1" and press Enter.
When the cli> prompt reappears, the controller has rebooted.
To reboot the entire JBOD expansion unit:
1.
Verify that no data I/O activity is in progress.
2.
Turn the power supply switch (switches) OFF.
3.
Wait 10 seconds.
4.
Turn the power supply switch (switches) ON.
See page 27, Figure 5.
A controller reboot does NOT meet the system restart
requirements for a firmware upgrade.
Caution
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vessjbod 1730Vessjbod 1740Vessjbod 1830Vessjbod 1840

Table of Contents