System overview CPX-F8DE-P
2.4.2

Rotary indexing table

This application example shows the possible use of 2 channel pairs for 4 positions of a rotary indexing
table. It involves the use of 4 N/O contacts that alternately signal the rotational position of the rotary
indexing table.
Fig. 19: Rotary indexing table with 4 rotational positions
The other channel pairs on the input module can be used to evaluate other sensors on a loading and
an unloading station.
When connecting the sensors (e.g. SMT-8M-A), the use of pre-assembled Y-cables from the NEBU
modular cable system is recommended è  www.festo.com/catalogue.
è Fig. 19 shows the circuitry of channel pairs with independent sensors. This involves the channel
pairs being set with the following function modes:
Channel pair
E0/E1
E2/E3
Tab. 23
This application example can also be implemented using electronic sensors (2-wire or 3-wire sensors).
46
Mode
Comment
9
Evaluation of 4 positions of the rotary indexing table.
9
Festo — CPX-F8DE-P — 2022-10d